| Job name | Numer of DAEs | tmax (s) | Submitted | Completed | Status |
|---|---|---|---|---|---|
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 3600 | 17:05:33 15/03/22 | 17:07:05 15/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 1600 | 16:56:42 15/03/22 | 16:58:00 15/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 1600 | 10:42:16 15/03/22 | 10:42:28 15/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 14:17:15 14/03/22 | 14:18:01 14/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 14:16:00 14/03/22 | 14:16:48 14/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 1600 | 16:51:42 11/03/22 | 16:51:57 11/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 0 | 16:49:24 10/03/22 | 16:49:34 10/03/22 | Error |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 1643 | 16:48:07 10/03/22 | 16:48:19 10/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 0 | 16:40:11 10/03/22 | 16:40:23 10/03/22 | Error |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 0 | 13:57:10 10/03/22 | 13:57:20 10/03/22 | Error |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 11:13:46 10/03/22 | 11:14:32 10/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 11:11:32 10/03/22 | 11:12:22 10/03/22 | Finished |
|
Gr/NMC single cell (Ecker et al.) 1C discharge
▾
Ecker, M. et al. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: I. Determination of Parameters. J. Electrochem. Soc. 162, A1836–A1848 (2015). Ecker, M., Käbitz, S., Laresgoiti, I. & Sauer, D. U. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: II. Model Validation. J. Electrochem. Soc. 162, A1849–A1857 (2015). |
30x30 + 20 + 30x30 | 3795 | 16:49:41 09/03/22 | 16:49:52 09/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 0 | 15:47:36 08/03/22 | 15:47:45 08/03/22 | Error |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 3440 | 14:49:51 08/03/22 | 14:50:03 08/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 11:19:37 08/03/22 | 11:20:28 08/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 11:19:08 08/03/22 | 11:20:03 08/03/22 | Finished |
|
Typical Gr/NCA C/3 discharge
▾
Graphite Anode (Ecker et al.) + typical Nickel Cobalt Aluminium (NCA) Cathode |
50x50 + 30 + 50x50 | 10218 | 18:33:50 07/03/22 | 18:34:04 07/03/22 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 18:11:25 07/03/22 | 18:11:35 07/03/22 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 18:09:10 07/03/22 | 18:09:19 07/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 72320 | 16:50:40 07/03/22 | 16:50:59 07/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
20x10 + 10 + 20x10 | 72310 | 16:45:52 07/03/22 | 16:46:12 07/03/22 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 72630 | 15:53:52 07/03/22 | 15:54:29 07/03/22 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 0 | 12:33:04 02/03/22 | 12:33:16 02/03/22 | Error |