Job name | Numer of DAEs | tmax (s) | Submitted | Completed | Status |
---|---|---|---|---|---|
Gr/NMC discharge/charge
▾
The current defined as Sin(c*t) |
30x30 + 20 + 30x30 | 10000 | 01:10:44 28/08/20 | 01:18:56 28/08/20 | Finished |
Gr/NMC - non-monotonic diffusivity in anode and cathode
▾
1C discharge rate |
30x50 + 20 + 30x30 | 3771 | 17:06:49 27/08/20 | 17:07:26 27/08/20 | Finished |
Gr/LFP 1C square wave
▾
1 min pulse + 1 min relaxation |
50x100 + 30 + 50x100 | 7355 | 13:31:00 26/08/20 | 13:34:47 26/08/20 | Finished |
Gr/LFP 5C square wave
▾
1 min pulse + 1 min relaxation |
50x100 + 30 + 50x100 | 1447 | 13:24:38 26/08/20 | 13:25:41 26/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3695 | 10:40:53 26/08/20 | 10:41:14 26/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3695 | 10:40:06 26/08/20 | 10:40:24 26/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3695 | 10:38:53 26/08/20 | 10:39:14 26/08/20 | Finished |
LG M50 21700 5Ah battery example
▾
Variable current, constant diffusivity in solid |
30x30 + 20 + 30x30 | 166198 | 11:58:42 24/08/20 | 12:01:47 24/08/20 | Finished |
LG M50 21700 5Ah battery example
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 166198 | 11:58:18 24/08/20 | 12:01:28 24/08/20 | Finished |
LG M50 21700 5Ah battery example
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 166198 | 11:56:34 24/08/20 | 11:58:16 24/08/20 | Finished |
LG M50 21700 5Ah battery example (double particle size)
▾
Variable current, constant diffusivity in solid, double particle size in Anode (10% of particles in the anode have x3 size) |
30x30 + 20 + 30x30 | 180000 | 18:51:56 22/08/20 | 18:53:48 22/08/20 | Finished |
5C square wave test
▾
Submitted from my phone |
50x50 + 20 + 50x50 | 1487 | 11:39:52 22/08/20 | 11:40:35 22/08/20 | Finished |
DC424
▾
test |
30x30 + 20 + 30x30 | 3720 | 16:35:14 20/08/20 | 16:35:31 20/08/20 | Finished |
Golmon et al
▾
This simulation was labeled as private. |
100x60 + 50 + 100x50 | 214 | 15:24:51 20/08/20 | 15:25:10 20/08/20 | Finished |
Gr/NMC single cell (Ecker et al.) 1C discharge
▾
Ecker, M. et al. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: I. Determination of Parameters. J. Electrochem. Soc. 162, A1836–A1848 (2015). Ecker, M., Käbitz, S., Laresgoiti, I. & Sauer, D. U. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: II. Model Validation. J. Electrochem. Soc. 162, A1849–A1857 (2015). |
30x30 + 20 + 30x30 | 3795 | 16:47:17 19/08/20 | 16:47:33 19/08/20 | Finished |
Gr/NMC single cell (Ecker et al.) 1C discharge
▾
Ecker, M. et al. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: I. Determination of Parameters. J. Electrochem. Soc. 162, A1836–A1848 (2015). Ecker, M., Käbitz, S., Laresgoiti, I. & Sauer, D. U. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: II. Model Validation. J. Electrochem. Soc. 162, A1849–A1857 (2015). |
30x30 + 20 + 30x30 | 3795 | 16:45:18 19/08/20 | 16:45:38 19/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3700 | 16:40:46 19/08/20 | 16:41:04 19/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3695 | 16:34:08 19/08/20 | 16:34:28 19/08/20 | Finished |
Typical Gr/LFP 1C discharge
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3695 | 16:25:25 19/08/20 | 16:25:42 19/08/20 | Finished |
Gr/NMC single cell (Ecker et al.) - full Drive Cycle
▾
Drive Cycle example (with 0.1 sec. resolution in time) |
30x50 + 20 + 30x50 | 6049 | 23:33:50 16/08/20 | 23:47:24 16/08/20 | Finished |
Gr/NMC single cell 1C discharge - test
▾
Lower temperature test |
30x30 + 20 + 30x30 | 3746 | 23:26:48 16/08/20 | 23:27:08 16/08/20 | Finished |
Private job example
▾
This simulation was labeled as private. |
75x50 + 21 + 55x50 | 3787 | 16:38:32 16/08/20 | 02:03:14 17/08/20 | Finished |
Gr/LFP 1C discharge - more accurate diffusivity in Anode
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode |
50x50 + 30 + 50x50 | 3690 | 02:05:42 16/08/20 | 16:01:34 19/08/20 | Finished |
Gr/NMC single cell (Ecker et al.) 5C discharge
▾
Roughly approximated diffusivity in solid (much smoother fits) |
75x500 + 21 + 55x500 | 715 | 02:02:54 16/08/20 | 02:25:15 16/08/20 | Finished |
Gr/NMC (more accurate diffusivity fits) - 5C discharge
▾
x10 discretisation points in solid, 5C discharge rate |
75x500 + 21 + 55x500 | 546 | 01:58:39 16/08/20 | 02:23:39 16/08/20 | Finished |