Job "Half_cell_test_1" status: Finished

Description: Typical LFP Cathode. 1C discharge rate corresponds to 1 A.

Job submitted: Tue, 27 Apr 2021 14:27:41 +0100

Job completed: Tue, 27 Apr 2021 14:27:51 +0100

Number of DAEs: 3028 (FV method)

Total (dis)charge time: 3620 s.

Stopped because the battery voltage reached Vmin = 3.2 V




Simulation result preview:
Voltage and currents Concentrations and potentials Parameters



Download all simulation results:

data_and_plt_files.zip





The zip-file contains text data-files with the simulation results (voltages, currents, concentrations of Li ions, potentials) in a plain text format ready to be imported into any third-party post-processing software (e.g. Microsoft Excel, LibreOffice Calc, MATLAB, etc.).

In addition to the data-files, the zip contains text plt-files that can be used to produce publish ready plots in gnuplot.




➠ Review all parameters & Resubmit the simulation

This will create a new instance of the simulation parameters. The current simulation will be unaffected.