Description: Ecker battery, 2x500x500 finite volumes (stress test).
Job submitted: Tue, 04 Aug 2020 17:44:08 +0100
Job completed: Sun, 09 Aug 2020 15:08:08 +0100
Number of DAEs: 501998 (FV method)
Total (dis)charge time: 385 s.
The zip-file contains text data-files with the simulation results (voltages, currents, concentrations of Li ions, potentials) in a plain text format ready to be imported into any third-party post-processing software (e.g. Microsoft Excel, LibreOffice Calc, MATLAB, etc.).
In addition to the data-files, the zip contains text plt-files that can be used to produce publish ready plots in gnuplot.
➠ Review all parameters & Resubmit the simulation
This will create a new instance of the simulation parameters. The current simulation will be unaffected.