| Job name | Numer of DAEs | tmax (s) | Submitted | Completed | Status |
|---|---|---|---|---|---|
|
Gr/NMC single cell (Ecker et al.) 1C discharge
▾
Ecker, M. et al. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: I. Determination of Parameters. J. Electrochem. Soc. 162, A1836–A1848 (2015). Ecker, M., Käbitz, S., Laresgoiti, I. & Sauer, D. U. Parameterization of a Physico-Chemical Model of a Lithium-Ion Battery: II. Model Validation. J. Electrochem. Soc. 162, A1849–A1857 (2015). |
30x30 + 20 + 30x30 | 3795 | 15:52:51 07/02/23 | 15:52:58 07/02/23 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 14:48:12 07/02/23 | 14:48:20 07/02/23 | Finished |
|
Mazumder battery 1C discharge - updated - restrict t_max
▾
Mazumder model validation: discharge at 1C over 3800s, timestep of 1s from 100% SOC. Fixed U_n AND U_p. Updated k0 (divided by the Faraday constant), surface area A, initial concentration in the electrolyte, input current. Note I use 1/2 of electrode area (since the actual number, 10452 cm^2, does not fit into the input field). I reduce the input current correspondingly (-3A instead of -6A). This will not affect the input current density which is I/A. |
50x50 + 25 + 36x50 | 2000 | 14:58:00 02/02/23 | 14:58:07 02/02/23 | Finished |
|
Mazumder battery 1C discharge - updated - restrict t_max
▾
Mazumder model validation: discharge at 1C over 3800s, timestep of 1s from 100% SOC. Fixed U_n AND U_p. Updated k0 (divided by the Faraday constant), surface area A, initial concentration in the electrolyte, input current. Note I use 1/2 of electrode area (since the actual number, 10452 cm^2, does not fit into the input field). I reduce the input current correspondingly (-3A instead of -6A). This will not affect the input current density which is I/A. |
50x50 + 25 + 36x50 | 3800 | 14:56:46 02/02/23 | 14:57:14 02/02/23 | Finished |
|
Mazumder battery 1C discharge - updated - restrict t_max
▾
Mazumder model validation: discharge at 1C over 3800s, timestep of 1s from 100% SOC. Fixed U_n AND U_p. Updated k0 (divided by the Faraday constant), surface area A, initial concentration in the electrolyte, input current. Note I use 1/2 of electrode area (since the actual number, 10452 cm^2, does not fit into the input field). I reduce the input current correspondingly (-3A instead of -6A). This will not affect the input current density which is I/A. |
50x50 + 25 + 36x50 | 3800 | 14:55:27 02/02/23 | 14:55:51 02/02/23 | Finished |
|
Li diffusivity - 10e-6
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 3683 | 12:19:45 02/02/23 | 12:19:52 02/02/23 | Finished |
|
Li diffusivity - 10e-6
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 3683 | 12:17:27 02/02/23 | 12:17:35 02/02/23 | Finished |
|
Li diffusivity - 10e-11
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 3680 | 12:16:56 02/02/23 | 12:17:02 02/02/23 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 12:06:15 02/02/23 | 12:06:23 02/02/23 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 3683 | 12:03:49 02/02/23 | 12:03:55 02/02/23 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
This simulation was labeled as private. |
50x50 + 30 + 50x50 | 3680 | 11:33:44 02/02/23 | 11:33:51 02/02/23 | Finished |
|
Gr/NMC single cell (Ecker et al.) 1C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 3780 | 08:27:30 02/02/23 | 08:28:26 02/02/23 | Finished |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 09:35:00 31/01/23 | 09:35:08 31/01/23 | Finished |
|
LG M50 test - Updated parametrisation
▾
Chang-Hui Chen et al. 2020 J. Electrochem. Soc. 167 080534 |
30x30 + 20 + 30x30 | 180000 | 11:26:12 30/01/23 | 11:26:48 30/01/23 | Finished |
| New | 30x30 + 20 + 30x30 | 0 | 17:23:10 29/01/23 | 17:23:15 29/01/23 | Error |
|
Typical Gr/LFP 1C discharge simulation
▾
Graphite Anode (Ecker et al.) + typical LFP Cathode. 1C discharge rate corresponds to 1 A. |
50x50 + 30 + 50x50 | 3680 | 09:47:24 29/01/23 | 09:47:31 29/01/23 | Finished |
|
LG M50 test - 2C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 5543 | 09:07:56 29/01/23 | 09:09:20 29/01/23 | Finished |
|
LG M50 test - 1C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 7415 | 08:50:18 29/01/23 | 08:53:50 29/01/23 | Finished |
|
LG M50 test - 1C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 7361 | 08:16:15 29/01/23 | 08:19:49 29/01/23 | Finished |
|
LG M50 test - 1C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 7375 | 07:22:13 29/01/23 | 07:25:50 29/01/23 | Finished |
|
LG M50 test - 1C discharge
▾
This simulation was labeled as private. |
30x30 + 20 + 30x30 | 3593 | 07:12:39 29/01/23 | 07:14:51 29/01/23 | Finished |